aquarite 900 manual

Hayward AquaRite 900 Manual⁚ A Comprehensive Guide

This manual provides a comprehensive guide to the Hayward AquaRite 900 salt chlorination system, covering installation, operation, maintenance, troubleshooting, and safety precautions. Whether you’re a new pool owner or an experienced user, this manual will help you get the most out of your AquaRite 900 system and ensure a safe and enjoyable swimming experience.

Introduction

The Hayward AquaRite 900 is a revolutionary salt chlorination system that provides a convenient and efficient way to maintain crystal-clear, sparkling pool water. This system eliminates the need for harsh chemicals, offering a more natural and enjoyable swimming experience. The AquaRite 900 utilizes a salt-based electrolysis process to generate chlorine, effectively sanitizing your pool water while keeping it soft and comfortable on your skin. With its advanced features, user-friendly interface, and reliable performance, the AquaRite 900 is a popular choice for pool owners seeking a hassle-free and environmentally conscious approach to pool care.

Understanding the AquaRite 900 System

The Hayward AquaRite 900 system utilizes a simple yet effective process to maintain your pool water. It converts ordinary table salt into chlorine, eliminating the need for harsh chemicals. The system consists of a control unit and an electrolytic cell. The control unit monitors and regulates the chlorine generation process, while the cell, containing titanium plates, facilitates the conversion of salt into chlorine. The AquaRite 900 also features a built-in flow sensor that ensures proper water flow through the cell for optimal chlorine production. The system’s advanced technology automatically adjusts chlorine output based on factors like water temperature, sunlight exposure, and pool usage, providing consistent sanitation without over-chlorination.

Installation and Setup

Installing the AquaRite 900 system involves connecting the control unit and electrolytic cell to your existing pool equipment. Ensure you have the necessary tools and materials, including a suitable location for the control unit and a secure mounting point for the cell. The installation process typically involves connecting the power supply, plumbing the cell into your pool’s circulation system, and wiring the control unit to your existing system. Before turning on the system, check all connections and ensure proper grounding to prevent electrical hazards. Refer to the AquaRite 900 installation manual for detailed instructions and specific requirements for your pool setup.

Connecting Power and the Cell

Connecting the power supply to the AquaRite 900 control unit is crucial for system operation. Ensure you have a dedicated 120-volt outlet with a ground fault circuit interrupter (GFCI). Connect the power cord to the control unit, and then plug it into the outlet. Next, connect the cell to the plumbing system. The cell typically connects to your pool’s return line, ensuring the chlorinated water is distributed throughout the pool. Use the provided fittings and hoses to secure the cell connection, ensuring a tight seal to prevent leaks. After connecting the power and plumbing, double-check all connections for tightness and proper grounding before turning on the system.

Setting the Cell Type

The AquaRite 900 system allows you to set the cell type to match your pool’s specific requirements. This is typically done during initial setup but can be adjusted later if needed. To set the cell type, press the “Diagnostics” button five times until the “Cell Type” display appears. Use the “Up” and “Down” arrows to select the appropriate cell type. For example, if you have a standard AquaRite 900 cell, choose the “T-Cell-9” option. If you have a larger cell, such as the “T-Cell-15,” select that option instead. Once you’ve chosen the correct cell type, press the “Diagnostics” button again to confirm your selection. The system will then use this information to optimize chlorine production for your pool.

Operation and Maintenance

The AquaRite 900 system is designed for effortless operation and minimal maintenance. Once installed and set up, it automatically produces chlorine to keep your pool clean and sanitized. However, regular monitoring and maintenance are essential to ensure optimal performance and longevity. This includes checking the salt level, inspecting and cleaning the cell, and addressing any common issues that may arise. By following the recommended maintenance procedures, you can enjoy a sparkling clean pool and minimize the need for manual chlorine additions.

Salt Level Monitoring

Maintaining the correct salt level is crucial for the efficient operation of your AquaRite 900 system. The ideal salt concentration for optimal chlorine production is between 3,000 and 3,500 ppm (parts per million). To check the salt level, press the diagnostics button five times on the control panel and wait for the reading to stabilize. If the salt level falls below the recommended range, add salt to the pool until the desired level is reached. Regular salt level monitoring ensures consistent chlorine production and prevents damage to the electrolytic cell.

Cell Inspection and Cleaning

Regular inspection and cleaning of the electrolytic cell are essential for maintaining its efficiency and extending its lifespan. Turn off power to the AquaRite before removing the cell. Inspect the cell for scale formation (light colored crusty or flaky deposits) on the plates and for any debris that may have passed through the filter and accumulated on the plates. If no deposits are visible, reinstall the cell. If scale is present, clean the cell using a Hayward cell cleaning solution or a mild vinegar solution. Rinse the cell thoroughly with clean water after cleaning. Remember to always follow the manufacturer’s instructions for cleaning and maintenance procedures.

Troubleshooting Common Issues

While the AquaRite 900 is generally reliable, you may encounter some common issues. If the system displays “No Flow” or “Check Cell,” ensure proper water flow through the system and inspect the cell for blockages or scaling. If the salt level is consistently low, check the salt level in the pool and add more as needed. If the system doesn’t produce chlorine, confirm the cell is producing chlorine by setting its output level to 100, waiting a few minutes, and observing the flow from your returns. If you see a cloud of tiny bubbles coming from the returns, the cell is working. If you are unable to resolve the issue, consult the Hayward website for troubleshooting tips or contact Hayward customer support for assistance.

Advanced Features

The AquaRite 900 offers advanced features to enhance pool sanitation and user convenience. The “Super Chlorination” mode allows for increased chlorine production, which can be useful for shocking the pool or dealing with high bather loads. This mode can be activated by flipping the main toggle switch from “Auto” to “Super” while the cell type is being displayed. The system also allows you to reset the average salt level, which can be helpful if you have recently added a significant amount of salt to the pool. This can be accomplished by pressing and holding the Diagnostics button until the Inspect Cell LED turns off (approximately 3-5 seconds). These advanced features provide greater control and flexibility for maintaining optimal water quality in your pool.

Super Chlorination Mode

The AquaRite 900’s Super Chlorination mode provides a temporary boost in chlorine production, ideal for situations like shocking the pool or handling heavy bather loads. To activate this mode, follow these steps⁚

  1. Ensure the cell type is being displayed on the system’s screen.
  2. Flip the main toggle switch from “Auto” to “Super”.

The system will now produce a higher level of chlorine until the switch is returned to the “Auto” position. Keep in mind that prolonged use of Super Chlorination mode can potentially lead to excessive scaling on the cell plates, so it’s best to use it sparingly and only when necessary. For optimal pool sanitation, regular maintenance and adherence to recommended salt levels are crucial.

Resetting the Average Salt Level

The AquaRite 900 system maintains an average salt level reading, which can be reset if necessary. This may be required after adding fresh salt to the pool or if the system has been experiencing inaccurate readings. To reset the average salt level, follow these simple steps⁚

  1. Press the “Diagnostics” button on the control panel five times. This will bring up the current salt level reading.
  2. Wait for the displayed number to stabilize, indicating the accurate salt level.
  3. Press and hold the “Diagnostics” button for approximately 3-5 seconds. This will reset the average salt level to the current reading.

The system will now use this new reading to determine the appropriate chlorine production levels. It’s crucial to ensure the salt level is within the recommended range for optimal system performance and water sanitation.

Safety Precautions

The AquaRite 900 system is designed for safe operation, but it’s crucial to follow these safety precautions to minimize the risk of injury or damage⁚

  • Always disconnect power to the AquaRite 900 system before performing any maintenance, cleaning, or repairs. This will prevent electrical shock and ensure a safe working environment.
  • Never allow children to operate or tamper with the system. Keep the control panel and wiring out of reach of children to prevent accidental contact or damage.
  • Use only Hayward-approved replacement parts and accessories to maintain the system’s performance and safety. Unauthorized parts could compromise the system’s integrity and lead to malfunctions or hazards.
  • If you notice any signs of damage to the system, such as cracked wiring, loose connections, or malfunctioning components, immediately disconnect power and contact a qualified service technician for repair.

By adhering to these safety guidelines, you can ensure a secure and enjoyable swimming experience for yourself and your family;

Electrical Safety

The AquaRite 900 system operates on electrical power, so it’s crucial to prioritize electrical safety during installation, operation, and maintenance.

  • Always ensure that the AquaRite 900 system is connected to a properly grounded electrical outlet. This will help prevent electrical shocks and ensure safe operation.
  • Use only copper conductors for wiring the AquaRite 900 system. Copper conductors are the safest and most reliable option for electrical installations.
  • Never attempt to repair or modify the AquaRite 900 system’s electrical components yourself. Only a qualified electrician should handle any electrical work related to the system.
  • Avoid using the AquaRite 900 system during electrical storms. Lightning strikes can damage the system’s electronics and pose a serious safety risk.

By following these electrical safety precautions, you can minimize the risk of electrical hazards and ensure a safe and worry-free swimming experience.

Child Safety

The AquaRite 900 system is designed for safe operation, but it’s essential to take precautions to protect children from potential hazards.

  • Never allow children to play near the AquaRite 900 system or its electrical components. Children should be supervised at all times around the pool and equipment.
  • Always ensure that the AquaRite 900 system’s control panel is out of reach of children. This will prevent them from accidentally tampering with the system’s settings or causing damage.
  • Keep the pool area free of clutter and obstacles that could pose a tripping hazard to children. A clean and organized pool area is essential for safety.
  • Install a pool fence that meets safety standards to prevent children from accessing the pool without supervision. A properly installed fence can significantly reduce the risk of accidental drownings.

By following these child safety measures, you can create a safe and enjoyable swimming environment for everyone.

Resources and Support

Hayward provides extensive resources and support to ensure you have everything you need to operate and maintain your AquaRite 900 system effectively.

  • The Hayward website offers a wealth of information, including detailed user manuals, troubleshooting guides, and FAQs. You can access this information online at Hayward.com.
  • Hayward also provides dedicated customer support channels for assistance with any questions or issues you may encounter. You can contact Hayward customer support by phone, email, or through their online contact form.
  • In addition to Hayward’s resources, many online forums and communities dedicated to pool maintenance and equipment offer valuable insights and advice from experienced pool owners.

By utilizing these resources, you can access expert guidance and troubleshooting support whenever needed.

Leave a Reply